Siemens load cell SIWAREX WL280 RN-S SA

956,00 1.841,00 

Ring torsion load cell made of stainless steel in the application ranges from 60kg to 60t

Artikelnummer: 7MH5113-1 Kategorie:

Beschreibung

SIWAREX WL280 RN-S SA is abending ring load cell. Particularly due to its high resolution this load cell can also be adapted to batching applications or legal-for trade scales.. WL280 RN load cells with a rated load up to 13t are additionally equipped with integral overload protection. Due to its low installation dimensions the load cell can be applied to a wide range of applications. The huge number of mounting accessories like self-aligning bearing, elastomer bearing, guide elements, etc. facilitates the various use and provide a secure installation as well as an optimal flow of forces.

 

Scope of application

container, conveyor and platform scales

 

Special characteristics

  • Wide range of load classes available
    High IP protection class
    Easy and fast installation due to the use of mounting units
    Suitable for use in legal metrology
    High accuracy classes

 

Features

SIWAREX WL280 RN-S SA load cells

Possible applications

Hopper, belt, platform and roller conveyor scales

Type of construction

Ring torsion load cell

Rated load/maximum load Emax.

  • 60 kg (132.28 lb)
  • 130 kg (286.60 lb)
  • 280 kg (617.29 lb)
  • 0.5 t (0.49 tn. l.)
  • 1 t (0.98 tn. l.)
  • 2 t (1.97 tn. l.)
  • 3.5 t (3.45 tn. L.)
  • 5 t (4.92 tn. l.)
  • 10 t (9.84 tn. l.)
  • 13 t (12.80 tn. l.)
  • 28 t (27.56 tn. l.)
  • 60 t (59.05 tn. l.)

Accuracy class according to OIML R60

C3

Max. scale interval nLC

3 000

Min. scale interval Vmin

E max/16 000

E max/17 500

Minimum application range Rmin(LC)

19 %

17 %

Combined error Fcomb

≤ ± 0.023% Cn

Repeatability Fv

≤ ± 0.01 % Cn

Return of zero signal

≤ ± 0.0167 % Cn1)

Creep error Fcr

  • 30 min

≤ ± 0.0245 % Cn1)

  • 20 … 30 min

≤ ± 0.0053 % Cn1)

Temperature coefficient

  • Zero signal TKo

≤ ± 0.004 % Cn/5K

  • Characteristic value TKc

≤ ± 0.004 % Cn/5K

Min. dead load Emin

≥ ± 0 % Emax

Max. working load Lu

200 % Emax

150% Emax

Breaking load Ld

500 % Emax

300% Emax

300% Emax

Safe side load LIq

75 % Emax

100% Emax

75 % Emax

Deflection hn at Emax

0.07 mm

0.1 ± 0.02 mm

0.11 … 0.2 mm

Overload protection

Integrated

Integrated

Integrated at 13 t

Supply voltage Usr (reference value)

15 V

10 V

15 V

Supply voltage (range)

5 … 30 V+

Rated characteristic value Cn

1 mV/V

2 mV/V

2 mV/V

Tolerance Dc of characteristic value

Up to 500 kg (1 102.31 lb): 0.01 mV/V

From 500 kg (1 102.31 lb): 0.1 mV/V

Tolerance Do of zero signal

≤ ± 1.0% Cn

Input resistance Re

60 kg (132.28 lb): 1 260 Ω ± 100 Ω

130 kg (286.60 lb): 1 260 Ω ± 100 Ω

280 kg (617.29 lb): 1260 Ω ± 250 Ω

1 100 Ω ± 100 Ω

13 t: 1 200 Ω ± 100 Ω

28 t: 1 075 Ω ± 100 Ω

60 t: 1 350 Ω ± 200 Ω

Output resistance Ra

1 020 Ω ± 0.5 Ω

1 025 Ω ± 25 Ω

13 t: 1 000 Ω ± 0.5 Ω
28 t: 930 Ω ± 0.5 Ω
60 t: 1 175 Ω ± 0.5 Ω

Insulation resistance Ris

≥ 5 000 MΩ

≥ 5 000 MΩ

≥ 5 000 MΩ

Rated temperature range Btn

-10 … +40 °C (14 … 104 °F)

Operating temperature range Btu

-35 … +70 °C (-31 … 158 °F)

Storage temperature range Bts

-50 … +90 °C (-58 … 194 °F)

Sensor material (DIN)

Stainless steel EN 1.4542

Degree of protection according to EN 60529; IEC 60529

IP66/68

Recommended tightening torque of the fixing screws

8 Nm

14 Nm (0.5 … 5 t)

10 Nm (10 t)

Current calibration2)

Standard

Ex protection to ATEX (optional)

II 1 G Ex ia IIC T4 Ga

II 1 D Ex ia IIIC T73 °C Da

II 3 G Ex ic IIC T4 Gc

II 3 G Ex nA IIC T4 Gc

II 3 G Ex tc IIIC T63 °C Dc

Cable connection

Function

Color

  • EXC +

Pink

  • EXC –

Gray

  • SIG +

Brown

  • SIG –

White

  • Shield (not connected to the load cell body)

Transparent

1) For rated temperature -10 … +40 °C (14 … 104 °F)

2) Current calibration: rated characteristic value and output resistance are adjusted so that the output current is calibrated within 0.05 % of a reference value. This makes it easier to connect several load cells in parallel.

Drawings

SIWAREX WL280 RN-S SA load cell 60 … 280 kg (132.28 … 617.29 lb), dimensions in mm (inch)

 

SIWAREX WL280 RN-S SA load cell, 0.5 and 1 t (0.49 and 0.98 tn. l.), dimensions in mm (inch)

 